top of page

Create Your First Project
Start adding your projects to your portfolio. Click on "Manage Projects" to get started
2900 sq. ft. Home, Vero Beach, Florida
Project type
Mechanical Plan
Date
April 1st 2026
Location
Vero Beach, Florida
Role
Mechanical Engineer
Project type
Residential
Outside Summer Design Temperatures
91
Inside Summer Design Temperature
75 F
Outdoor Winter Design Temperature
43
Inside Winter Design Temperature
70 F
Permit-ready single-zone HVAC design for a 2,900 sq. ft. coastal home in Vero Beach, Florida. Precisely calculated via Manual J, S, and D around a 5-ton Trane split heat pump (1,817 CFM), the plan efficiently manages high regional humidity by countering a 46,439 Btuh peak summer load (11,771 Btuh latent capacity) and a 33,952 Btuh winter heat loss. The seamless layout integrates complete whole-house duct routing, performance schedules, and code-compliant fresh air ventilation specifications.